• Home
  • Technology
    BioClavis Technology

    High-throughput transcriptomics with TempO-Seq

    Explore the assay chemistry, workflow, technical resources, publications and platform advantages.

    View Technology

    Technology Overview

    TempO-Seq TempO-Seq Workflow TempO-Span

    Technical Resources

    Resources Publications FAQs Detector Oligo Design Limitations of RNA-seq Patents
  • Products
    BioClavis Products

    TempO-Seq assays, panels & analysis tools

    Browse BioClavis product pages, clinically relevant sample formats, data tools and partner programmes.

    View Products

    Platforms & Panels

    Panels TempO-Seq TempO-LINC TempO-Seq miRNA

    Samples & Data

    FFPE TempO-Seq Blood Spot TempO-Seq Portal Assays

    Partners & Programmes

    Our Distributors Collaborations Request Information
  • Services
    BioClavis Services

    From study design to biological insight

    Access transcriptomics services for pharma, academic and clinical programmes with downstream bioinformatics support.

    Explore Services

    Research Services

    Pharma Toxicology & Safety Academic Research Clinical Research

    Analysis & Customer

    Bioinformatics Services Customer Page Contact BioClavis
  • News
  • Conferences
  • About
    About BioClavis

    Company, community & careers

    Learn about BioClavis, its global access, community work and opportunities to join the team.

    Our Story

    Company

    Our Story Our Distributors

    Community & Team

    CSR Careers Contact BioClavis
  • Customer Page
  • FAQ's
  • Enquiries
TempO-Seq support

Frequently asked questions.

Find answers about TempO-Seq kits and service projects, sample inputs, panels, data analysis, the TempO-Seq Portal and common troubleshooting questions.

Kits + services

Run TempO-Seq in your lab or work with BioClavis.

BioClavis supports both TempO-Seq kit-based workflows and complete service projects, including custom panels and downstream bioinformatics.

Request a quote

Showing all 25 FAQs

Browse by topic Kits & Service ProjectsSamples & Assay InputsPanels & Assay DesignData AnalysisPortal & TroubleshootingTempO-Seq miRNA

Still need help with a project, kit, sample type or assay?

Contact BioClavis
Kits & Service Projects

Kits & Service Projects

Kits, quotations, turnaround, customer access and project delivery.

6 FAQs
How do I get a quote for service projects or kits?

BioClavis supports both kit-based and service-based TempO-Seq workflows. For a quotation, email info@bioclavis.co.uk or use the Enquiries page.

What is the usual turnaround time for service projects?

A typical TempO-Seq service project is completed in approximately 4–6 weeks after BioClavis receives the samples. Timing can vary with project scope, sample type and assay requirements.

How much will a TempO-Seq project cost?

Pricing depends on project size, panel content, sample number and whether you are purchasing kits or using BioClavis services. TempO-Seq is designed to reduce the cost of transcriptome analysis, with larger studies generally benefiting most from multiplexing. Contact BioClavis for a quotation.

Does BioClavis work with researchers and companies worldwide?

Yes. BioClavis supports research internationally and works through a global distributor network. Visit Our Distributors or contact BioClavis for the best route in your region.

Where do I submit sample information?

Sample preparation and submission information is available through the BioClavis Customer Page. If you need access or are unsure which form applies to your project, please contact BioClavis.

How do I download FASTQ files from a service project?

FASTQ files generated for service projects are made available as part of project delivery. Use the Customer Page for customer resources, or contact BioClavis if you need access instructions for your project files.

Samples & Assay Inputs

Samples & Assay Inputs

Extraction, sample compatibility, RNA input and FFPE handling.

4 FAQs
Do I need to extract RNA or DNA for TempO-Seq?

No. TempO-Seq can work directly from crude lysates and does not require nucleic acid extraction, purification or cDNA synthesis for supported workflows.

What sample types can I run with TempO-Seq?

TempO-Seq supports a broad range of inputs, including cell or organoid lysates, isolated RNA, whole blood, dried blood spots, FFPE tissue and other low-input or clinically relevant samples. If your sample type is not listed, contact BioClavis to discuss compatibility.

How much RNA should I use for TempO-Seq?

TempO-Seq can work across a wide range of RNA inputs. For purified RNA workflows, BioSpyder guidance identifies 100 ng/µL as an ideal target concentration, while other TempO-Seq workflows can use substantially lower input amounts depending on sample type and assay design.

Should I use charged or uncharged slides for FFPE tissue?

Charged slides are generally preferred because tissue adheres more securely and there is less concern about sample loss. Uncharged slides can also be used when appropriate, including with a coverslip.

Panels & Assay Design

Panels & Assay Design

Gene content, custom panels, S1500+ and manifests.

4 FAQs
How many genes can I test at once?

TempO-Seq supports highly multiplexed assays ranging from focused panels with tens of targets to panels with tens of thousands of genes, up to whole-transcriptome content. BioClavis offers whole-transcriptome, surrogate and custom panel options.

Can I customise panels?

Yes. BioClavis can design fully customisable panels around transcript variants, mutations, isoforms or other targets of interest. Contact BioClavis to discuss a custom panel.

What is the difference between S1500+ and a whole-transcriptome panel?

S1500+ is a surrogate transcriptome panel designed to cover known biological pathways using a focused set of genes. Whole-transcriptome panels are designed to target all protein-coding genes, providing broader expression coverage.

Where can I find probe manifests for different panels?

Panel manifests are available through customer resources. Visit the Customer Page and use the manifests area to find available panel files.

Data Analysis

Data Analysis

Counts, normalisation, pathway analysis and downstream support.

4 FAQs
I am not a bioinformatician. How will I deal with the data?

TempO-Seq data analysis is substantially simplified compared with conventional RNA-Seq. BioClavis can provide gene-count CSV files and can also support custom bioinformatics, including exploratory analysis, differential expression, pathway analysis and other downstream workflows.

Can I use TempO-Seq data for pathway analysis?

Yes. TempO-Seq data can be used for pathway-level analysis and tools such as Connectivity Map (CMap) or BMDExpress 2, depending on the study design and analysis goals.

How do I normalise TempO-Seq data?

TempO-Seq data is typically aligned and delivered as raw counts without a single imposed normalisation method. Multiple normalisation approaches can be used depending on the experimental design. A published comparison of TempO-Seq normalisation methods is available through NCBI.

How are FASTQ files converted to read counts?

BioSpyder documentation describes quantifying raw counts from aligned reads with the QuasR R package using default parameters. Your exact project output and analysis route can depend on the assay and delivery workflow.

Portal & Troubleshooting

Portal & Troubleshooting

Sample sheets, PCA, alignments, uploads and portal behaviour.

6 FAQs
Do I need to upload a sample sheet to start analysis with TempO-Seq?

A count table is required for quality-control and analysis tools, while a sample sheet is optional. Uploading a sample sheet can preserve plate-order sample names and lets the Description column be used to designate replicate groups for PCA.

How do I designate replicates for PCA in TempO-SeqR?

Use the Description column in the sample sheet to identify replicates. Give samples in the same replicate group the same label, such as Liver, Kidney or Group1, and upload the sample sheet with the count table.

How long is an alignment expected to take?

Alignment time depends on the number and size of FASTQ files. BioSpyder guidance gives a typical estimate of about one minute per five million reads, although heavy system load can increase the time. Check Alignment History for current status.

My TempO-Seq Portal alignment failed. What happened and what should I do?

Alignment can fail during FASTQ validation or while mapping reads. A FASTQ-validation failure usually indicates a formatting issue in one or more files, while an incomplete alignment indicates a mapping-stage failure. If the problem persists, use the BioClavis Enquiries page for support.

Why are my files taking so long to upload to TempO-SeqR?

Upload speed depends on file size and your internet connection. Large FASTQ files can take time to transfer. If files still will not upload after an extended period, contact BioClavis for support.

How does TempO-Seq Portal treat paired samples?

TempO-Seq Portal treats paired samples as independent samples during analysis.

TempO-Seq miRNA

TempO-Seq miRNA

Sequencing guidance for miRNA workflows.

1 FAQ
What is the recommended read depth for the miRNome Panel?

The recommended sequencing depth is approximately 2–3 million reads per sample for the miRNome Panel.

No FAQs matched your search. Try a broader term or contact BioClavis.
Need more detail?

Talk to the BioClavis team.

Get help with kit selection, study design, custom panels, sample compatibility, service projects or downstream analysis.

Make an enquiry Customer Page
BioClavis
Homepage News Conferences Customer Page FAQ'S
Enquiries
TempO-Seq TempO-Seq Workflow Resources FAQs Publications Detector Oligo Design Limitations of RNA-seq TempO-Span Patents
Panels TempO-Seq TempO-LINC FFPE TempO-Seq Blood Spot TempO-Seq miRNA TempO-Seq Portal Assays Our Distributors Collaborations
Pharma Academic research Clinical research Bioinformatics services Customer Page
Our story Our Distributors. CSR Careers
Homepage TECHNOLOGY TempO-Seq TempO-Seq Workflow Resources FAQs Publications Detector Oligo Design Limitations of RNA-seq TempO-Span Patents Products Panels TempO-Seq TempO-LINC FFPE TempO-Seq Blood Spot TempO-Seq miRNA TempO-Seq Portal Assays Our Distributors Collaborations Services Pharma Academic research Clinical research Bioinformatics services Customer Page NewsConferences About Our story Our Distributors. CSR Careers Customer PageFAQ'S
BioClavis
Enabling high-throughput transcriptomics using TempO-Seq
Enquiries
Hours
Mon 9am - 6pm
Tue 9am - 6pm
Wed 9am - 6pm
Thu 9am - 6pm
Fri 9am - 6pm
BIOCLAVIS, LTD.

Carus House
201 Dumbarton Road
Clydebank, G81 4XJ
+44 (0) 141 286 5100
Contact
 
ABOUT

Our Story
CSR
Careers
TEMPO-SEQ

Overview
Resources
SERVICES

Pharma
Academic research
Clinical research
Sample submission
NEWS

EVENTS